60 amp service in detached garage 200' of service wire
Sep 20, 2011 · Electrical - AC & DC - 60 amp service in detached garage 200' of service wire - I have a detached garage that I would like to run electric too from my house. My house has 200 amp panel. I'll …
60-amp electric furnace wire size? - DoItYourself.com
Jun 3, 2009 · What size PVC conduit will this wire, plus a #12 neutral (for the condensate pump) fit in? 3/4" minimum will fit (2) #6 hots, (1) #10 ground, (1) #12 neutral. However, you can't just run the #12 …
Wire size for electric furnace - DoItYourself.com
Dec 31, 2019 · Electrical - AC & DC - Wire size for electric furnace - I bought a 15kw electric furnace. 240vac 1ph 60hz the manual says supply wire size must be in accordance with NEC codes. What …
2/0 wire connected to 60A circuit breaker? - DoItYourself.com
May 23, 2006 · Electrical - AC & DC - 2/0 wire connected to 60A circuit breaker? - A 60A double pole circuit breaker takes up to #2 wire, according to the markings on the breaker. Is there a way to …
What size ground wire for 60amps? - DoItYourself.com
Dec 27, 2020 · 6/3 Romex is rated 55 amps, but there is no 55 amp breaker made so by code you can go to the next size larger, which is 60 amps. However, if you use Romex it is required to be protected …
awg size for 60' underground line from house to shed for 60 amp
Jun 9, 2010 · Electrical - AC & DC - awg size for 60' underground line from house to shed for 60 amp - problem: I have a shed that is about 50 feet away from the house, and about 60 feet away from the …
Electric furnace wire/breaker size - DoItYourself.com
Nov 28, 2011 · Wire size for 60 amps is #6 Copper. The ground can be #10 if you are not using a cable. (NM-b) ***Edit: See other post for amended information of wire size*** When you say there is a …
Can 6/3 Romex support a 60amp breaker? - DoItYourself.com
Sep 27, 2007 · 6/3 is normally protected with a 60-amp breaker. Since there are no 55-amp breakers, code allows you to round up to the next larger standard size. Is 6/3 NM-B THHN? Yes and no. We all …
Wire size for a 60 amp circuit - DoItYourself.com
Nov 23, 2003 · Anyway, a 50 Amp circuit will probably be enough and I know that I should use 6-3 w/G to feed the subpanel and isolate the neutral bus bar from the ground bus bar in the subpanel. But if I …
Hot Tub Question wiring requirements - DoItYourself.com
Aug 10, 2024 · Electrical - AC & DC - Hot Tub Question wiring requirements - We are looking into getting a Viking Legacy 2. The requirements are 240/60. So correct me if I am wrong but here are my …